Hidden label. Privacy Policy. I have read and understand the Privacy Policy and Terms of Service. Unfortunately, UV can cause serious problems. Due to its higher energy, UV energy accelerates the aging process. Therefore, any energy below nm must be filtered or eliminated. A radiometer can also detect and measure infrared or IR. It can measure heat on surfaces. Technicians use them to measure and repair shorted wiring or overheating motors.
Simple radiometers are quick to measure because they only use one sensor and a wavelength range filter. Radiometers can be carried around and are portable, making them an economical and practical option. This instrument can detect and measure heat energy from surfaces and eliminate UV energy.
One sensor allows it to measure wavelengths quickly. Spectrometers measure wavelengths using multiple sensors, an optical grating to split the energy into parts, and a prism to detect it. The spectrometer creates an image of the output by taking a photo of the light. It works in the same way as a camera. They allow in light and then break down the signal to spread it over a sensor range. Based on the incoming signal amplitude, this sensor divides the wavelengths and scales them.
Like radiometers, spectrometers measure specific wavelengths. The main difference between spectrometers and radiometers is that they use an optical prism or multiple sensors and multiple wavelengths or component detectors to separate the incoming energy.
This page compares Radiometer vs spectrometer vs spectroradiometer and mentions difference between Radiometer, spectrometer and spectroradiometer.
Though all these instruments are used to detect color and light there are basic differences between them as outlined below. Following are the features of Radiometer. The DLP mirror does not significantly add to the price of the instrument. Aside from the cost, the detector area for DLP could be larger few mm instead of tens of microns which improves the Signal to Noise Ratio SNR and scan errors due to defective pixels and pixel to pixel non-uniformity are reduced because only a single element detector is used[Reference 2].
A spectroradiometer is a spectrometer with light intensity calibration. So the measured light at each wavelength will have a unit associated with it. The lighting passport offered by the company Allied Scientific Pro is an example of a spectroradiometer calibrated in photometric units. Please see www. In figure 3, two results from the measurements of lighting passport are shown. The left picture shows the relative intensity , the table on the right shows the total illuminance in lux or foot-candle.
Figure 3: The intensity measured by the spectro-radiometer is calibrated in units of Lux. The slider below the graph could be moved and hence ppfd value at each particular wavelength can be found. Figure 4: PPFD plot. One has to note that the radiometric irradiance units are valid over the entire electromagnetic range but the photometric units are valid only in the range nm.